Estimate the soffit you need for your eaves and gable rakes: square footage, panels and trim. It also works out the attic intake vent area under the code's 1/150 and 1/300 rules.

ft

Add up every eave side

in

Wall to back of fascia

ft
in
in

Coverage width

ft
%
$
Attic ventilation
sq ft
Rule

Soffit panels (incl. 10% waste)

15 panels

Soffit area
160.0 sq ft
Panel size
12 in ร— 12 ft (12 sq ft)
J/F-channel trim (approx.)
264 ft
Total vent area (1/300)
5.00 sq ft ยท 720 sq in
Intake (soffit) share, about half
360 sq in

Check the net free area (NFA) printed on your vented soffit or vents and use enough to reach the intake figure. Keep insulation baffles in place so air can flow from the soffit into the attic.

Venting follows IRC R806.2 (1/150 of attic area, or 1/300 when 40โ€“50% of the vent area is high on the roof and the rest at the eaves). Local codes and roof designs vary.

How to use the soffit calculator

  1. Add up the length of every eave you're covering, and measure the soffit width from the wall to the back of the fascia.
  2. Add gable rake soffits if your roof has them, and enter your panel's coverage width and length.
  3. Enter the attic floor area to see how much ventilation the code calls for and how much should come from the soffits.

Soffit formulas

Soffit area = eave length ร— soffit width (ft) + rake length ร— rake width (ft)
Panels = area ร— (1 + waste) รท panel coverage
Vent area = attic area รท 150 (or รท 300 if balanced) ยท soffit intake โ‰ˆ ยฝ of it

Example

120 ft of eaves ร— 16 in (1.333 ft) = 160 sq ft
12 in ร— 12 ft panels (12 sq ft): 160 ร— 1.10 รท 12 = 14.7 โ†’ 15 panels
1,500 sq ft attic, balanced 1/300: 5 sq ft = 720 sq in total, about 360 sq in at the soffits

Attic ventilation basics

  • The code rule: IRC R806.2 calls for net free vent area of at least 1/150 of the attic floor area, reduced to 1/300 when 40โ€“50% of it is in the upper part of the attic and the rest is at the eaves (or, in climate zones 6โ€“8, with a ceiling vapor retarder). Check the edition your area uses.
  • Intake and exhaust work together: soffit vents let cool air in low; ridge or roof vents let warm, moist air out high.
  • Don't block it: install insulation baffles so attic insulation doesn't cover the soffit vents.

For more on how venting ratios work, see the U.S. Department of Energy's Building America guide to calculating attic passive ventilation.

Choosing materials

MaterialNotes
VinylLow cost and low maintenance; sold solid or vented in panels
AluminumDurable, doesn't rot; often paired with aluminum fascia wrap
Fiber cementPaintable and fire resistant; heavier to install
WoodTraditional look; needs painting and can rot if moisture gets in

The soffit width comes from your rafter tails; the rafter length calculator includes the overhang. For wall and floor areas use the square footage calculator, and to price wood trim or blocking use the board foot calculator. More construction calculators.

Estimates for planning. Follow the panel manufacturer's instructions and your local building code for ventilation.

Frequently asked questions

How do I calculate how much soffit I need?

Multiply the total length of your eaves by the soffit width (the overhang, from wall to fascia) in feet. 120 feet of eaves with a 16-inch overhang is 120 ร— 1.333 = 160 square feet. Divide by the coverage of one panel and add 10% or so for waste and cuts.

How many soffit panels do I need?

Divide the soffit area by one panel's coverage. A 12-inch-wide, 12-foot panel covers 12 square feet, so 160 square feet needs 13.3 panels, about 15 with 10% waste. Panel sizes vary by brand (16-inch widths are common too), so use the coverage width on the packaging.

How much attic ventilation do I need?

Under the International Residential Code (R806.2), the net free vent area must be at least 1/150 of the attic floor area, or 1/300 when 40โ€“50% of the venting is in the upper part of the roof (such as ridge vents) and the rest at the eaves. A 1,500 sq ft attic needs 10 sq ft of vent area at 1/150, or 5 sq ft at 1/300.

How much of the ventilation should be in the soffits?

For balanced ventilation, roughly half (or slightly more) of the total net free area goes in the intake at the soffits, with the rest as exhaust near the ridge. For 5 square feet total, that's about 2.5 square feet, or 360 square inches, of soffit intake.

What is net free area (NFA)?

NFA is the actual open area air can pass through in a vent, after screens and louvers are taken into account, usually given in square inches per vent or per linear foot. Vented soffit panels and vent strips list their NFA on the packaging.

Do I need J-channel or F-channel?